Spectre

Spectre is the control program for a simple home-made spectrograph: a diffraction grating, whatever tube and mount you put it in, and one of the ZWO monochrome cameras. The optical layout does not matter - nothing in the program assumes a particular design, sensor size or camera model.

The goal is to shoot spectra and calibrate them, compare spectra against each other, plot them, and save them as 1-D FITS with the calibration written into the header - or export the data as CSV and the chart as SVG and PNG.

The main window: live frame with the band overlay, the extracted spectrum against the reference solar spectrum, and the graph below

And what comes out of it - the transmission curve of a no-name IR-pass filter, measured against a spectrum taken without it:

Transmission curve of an IR-pass filter

Implemented so far:

  • live view of the camera - the raw 16-bit linear frame, in real time, with exposure, gain, offset and USB bandwidth control, and a display stretch that only affects what you see, never the data;
  • crop (region of interest) with draggable lines: a spectrograph throws glare and the zero order across the sensor, and every measurement is done inside the crop only;
  • band geometry calibration - the tilt of the spectrum band against the frame axes, i.e. how the camera is rotated on the spectrograph, plus the band's centre line and edges;
  • shear calibration - the direction of the spectral lines, i.e. the tilt of the slit against the grating. Together with the band angle this gives the basis of the spectrum coordinate system: two vectors, X along the wavelength axis and Y along the spectral lines, neither perpendicular to the other nor to the frame edges;
  • 1-D spectrum extraction along that basis, shown as a strip and as a plot;
  • wavelength calibration against the solar spectrum - the main thing. A reference solar atlas (300-1130 nm) is blurred down to the instrument's resolution and drawn as a second strip flush under ours, resampled into our own pixel columns. Identify a line by clicking it on the reference and then on our spectrum; from three points on, X becomes nanometres, and the graph gets a wavelength scale and a colour strip showing where the visible range falls;
  • relative measurement - keep one spectrum aside as a baseline and everything is then read as a per cent of it. Shoot once without a filter, once with it, and the graph is the filter's transmission curve;
  • averaging the last N spectra, a plain arithmetic mean, to pull a noisy curve out of the grass;
  • dark calibration - seven covered frames medianed into a master dark, filed under the gain and exposure it belongs to and picked up again by itself whenever those two come back to it; or a flat bias level when there is no dark;
  • export - the curve as a two-column CSV, or as a finished picture, PNG at 3840x2160 and SVG beside it, with the grid, the colour strip and the lines that matter for astronomy marked;
  • saving frames as 16-bit FITS (plus .npy) with exposure, gain, sensor temperature, crop position and the calibration in the header, and replaying a saved frame instead of a camera, so everything can be worked on without hardware.

Not there yet: the 1-D FITS export, comparing several spectra side by side, and deciding whether the X -> wavelength mapping should stay a polynomial or become the physical grating formula.

Windows 10, Python 3.11+, pygame + Dear ImGui over OpenGL 3.3.

main.bat                                   # same as python main.py
python main.py                             # first ASI camera found
python main.py --file captures\name.fits   # replay a saved frame
python main.py --sim                       # synthetic spectrum, no hardware
python main.py --list                      # list cameras and exit
python tools/probe_camera.py               # check the camera without a GUI

Algorithm specs and accumulated traps live in docs/: TZ_BandAngle.md, TZ_Shear.md, TZ_Spectrum.md, TZ_Wavelength.md, KnowledgeBase.md.

Install

pip install -r requirements.txt

ASICamera2.dll from the ZWO ASI Camera SDK is needed. Searched in this order (spectre/asi_sdk.py, DEFAULT_DLL_PATHS):

  1. the SPECTRE_ASI_DLL environment variable;
  2. <project>/lib/ASICamera2.dll;
  3. C:\src\ZWOCameraSDK\lib\x64\ASICamera2.dll;
  4. C:\Program Files\ASIStudio\ASICamera2.dll;
  5. plain ASICamera2.dll somewhere on PATH.

Or point at it directly: python main.py --dll "C:\path\ASICamera2.dll".

Which Python ImGui binding

imgui-bundle (pip install imgui-bundle), and here is why:

  • pyimgui (the imgui package) is frozen on Dear ImGui 1.82 (2021) and barely moves;
  • imgui-bundle is alive, carries Dear ImGui 1.92, ImPlot (useful for spectrum plots later), docking, and - the point here - a ready pygame backend: imgui_bundle.python_backends.pygame_backend;
  • dearpygui is not an ImGui binding but a separate framework with its own render loop; it does not combine with pygame.

With pygame, ImGui renders through OpenGL, so the window is created with OPENGL | DOUBLEBUF | RESIZABLE and the camera frame is not blitted through pygame.surfarray but uploaded as a GL texture inside imgui.image().

One catch: the stock PygameRenderer only forwards navigation keys to ImGui, so imgui.is_key_pressed(imgui.Key.f) never fires and application shortcuts are impossible. spectre/imgui_backend.py has SpectreRenderer, which maps the whole keyboard and still feeds printable characters to text fields. Key repeat is left to ImGui itself (io.key_repeat_delay / io.key_repeat_rate): one-shot actions use is_key_pressed(key, repeat=False), repeating ones repeat=True.

Controls

Key Action
F fit the frame to the window
1 100 % zoom
+ / - zoom in / out (repeats)
arrows pan (repeats, Shift = faster)
mouse wheel zoom at the cursor
left drag pan
[ / ] exposure / 1.25 or x 1.25 (Shift = /2, x2)
, / . gain -5 / +5 (Shift = +-25)
Space pause / resume
A auto stretch on / off
B band overlay on / off
C whole frame / crop only
S save the current frame into captures/
H shortcuts window
Esc quit

Hovering the image shows the pixel coordinates and its value in ADU in the status line.

How it is put together

main.py                  window, event loop, CLI
spectre/asi_sdk.py       ctypes binding of ASICamera2.dll (from ASICamera2.h, SDK 1.21)
spectre/camera.py        grabber thread; AsiCamera (video/snap), FileCamera, SimulatedCamera
spectre/display.py       display stretch (LUT), frame statistics, GL texture
spectre/imgui_backend.py pygame backend for ImGui with the full keyboard mapped
spectre/darks.py         master dark: median of N covered frames, live subtraction
spectre/calib.py         all the geometry: band angle, shear, spectrum extraction
spectre/reference.py     reference solar spectrum: blur, resample into our pixels
spectre/wavelength.py    anchor points and the X -> wavelength polynomial
spectre/chart.py         the curve as a finished picture (matplotlib, PNG + SVG)
spectre/frameio.py       saving and loading frames (FITS / .npy), CSV export
spectre/app.py           application state, connection, frame pipeline
spectre/ui.py            ImGui panels, overlays, keyboard
spectre/settings.py      settings.json
tools/probe_camera.py    camera diagnostics from the console
tools/fetch_reference.py downloads data/solar_reference.csv from BASS2000
data/solar_reference.csv reference solar spectrum, 300-1130 nm at 0.1 nm
captures/                saved frames, exported CSV and charts
darks/                   master darks, dark_<gain>_<exposure key>.fit

Capture runs in its own thread; the UI thread never calls the SDK. It queues control changes (camera.set_control) and picks up the newest finished frame (camera.latest_frame) - if the UI cannot keep up, spare frames are dropped rather than queued.

Two capture modes switch automatically on the exposure (SNAP_THRESHOLD_US, 1 s):

  • video (ASIStartVideoCapture / ASIGetVideoData) for short exposures;
  • snap (ASIStartExposure / ASIGetDataAfterExp) for long ones. In snap mode a running exposure is aborted when a control changes, otherwise a 30 s exposure would make the interface look frozen. Progress is shown in the panel.

The camera data is never modified: the frame stays uint16 on a linear scale, and what reaches the screen is the result of a lookup table (black point / white point / midtone transfer function), uploaded as a single-byte GL texture (GL_R8 plus a swizzle to grey, with mipmaps so that thin spectral lines do not vanish when the view is zoomed out).

Saving frames, and working without a camera

Left panel, Save frame (or the S key): the current frame is written into captures/ next to the app, exactly as the camera delivered it - linear, 16-bit, no stretch. By default the crop is saved, not the whole frame; there is a checkbox for the whole frame. Formats:

  • FITS with a header: EXPTIME / EXPUS, GAIN, OFFSET, XBINNING, INSTRUME, CCD-TEMP, BITDEPTH, XPIXSZ, the crop position on the sensor (CROPX0...CROPY1) and, if the calibration has been done, its result (BANDANG, BANDCY, BANDW, BANDLO, BANDHI, BANDREFX);
  • .npy - the raw numpy array, no header.

Saved frames appear in the camera list as file: name.fits and are played back instead of a camera (FileCamera): the image, exposure and gain come from the file, the exposure controls are hidden, and everything else - crop, stretch, calibration, spectrum - works as on a live frame. To switch: Disconnect -> Refresh list -> pick the file -> Connect. From the command line: python main.py --file captures\name.fits.

The simulator (--sim) sits last in the camera list and is never selected on its own. It does not reproduce what a real spectrograph looks like (uniform band, full frame width, no glare) and is only good for checking that the code runs and the UI draws.

Crop (region of interest)

Right panel, Crop. Every spectrum algorithm works strictly inside the crop; results are converted back to full-frame coordinates.

  • Show full frame (key C) - the whole frame with four draggable red lines, everything outside the crop dimmed;
  • unchecked - only the crop is shown;
  • the bounds can also be typed with the sliders, and there is a reset button;
  • the crop is saved in settings.json.

Statistics, the histogram and the auto stretch are measured inside the crop too: letting the glare and the zero order set the display levels, or the numbers you read off the panel, is worse than useless.

Calibration: the band angle

Right panel, Band angle. Implemented as specified in docs/TZ_BandAngle.md:

  1. capture is paused and the crop is scanned top to bottom, one scan line per row (1 px steps), but the lines do not run along X - they are tilted: line number Y starts at (0, Y) on the left edge of the crop with slope dy/dx = tan(L);
  2. for every angle L from -10 to +10 degrees in 0.01 degree steps, the arithmetic mean of all pixels along the line is taken, giving array[L][Y] - a 1-D projection of the image. The mean, not a median: the spectrum covers only part of the width, and the mean still shows it as a bump;
  3. in each projection the 0.1 % and 99.9 % percentiles are taken and a level 25 % of the way between them; the two crossings of that level are found outwards from the peak of the projection, and the distance between them is the width of the bump (crossings are sub-pixel);
  4. the width-versus-angle array is Gaussian-filtered (5 samples) and its minimum taken. That angle is the direction of the spectrum, and the two crossings at that angle are the edges of the band.

The edges and the centre line are drawn over the image (never into the texture), key B. Curves shows the width curve before and after filtering, the projection at the chosen angle, and the range the curve covers - the range tells you at a glance how pronounced the minimum is on this particular frame.

Two things worth knowing in use:

  • the crossings are searched outwards from the peak, not inwards from the ends of the array. Otherwise stray light (the zero order, a reflection arc) crosses the level too and what gets measured is the distance to it rather than the width of the band - which made the answer depend on where the crop line was, down to flipping the sign of the angle;
  • the level is 25 %, not the midpoint: for a band with a flat top the half-maximum points barely move when the edges blur, so the width curve comes out flat and the minimum is picked by noise.

The crop has to be tall enough: a tilt of L costs the projection crop_width * tan(L) rows, and the band plus some background has to fit in what is left. Otherwise the large angles have no background left and the curve shoots up at its ends.

Calibration: shear and the basis

Right panel, Shear: spectrum basis, button Find shear (the band angle has to be measured first). Implemented as specified in docs/TZ_Shear.md: line directions from -10 to +10 degrees are tried in 0.05 degree steps, and for each one a 1-D projection along the wavelength axis is built - pixels are summed across the band width along the trial direction and divided by how many were summed. The sharpness of a projection is the RMS of the difference of two Gaussian blurs (scales 1 and 4, times the single blur scale parameter); the sharpest projection gives the direction of the spectral lines.

The result: the tilt of the lines against the frame Y axis, the shear as the departure from perpendicularity, du/dv (how far the wavelength coordinate slides per pixel across the band), and the basis itself - two unit vectors in frame coordinates. The sharpness curve is shown next to it.

Nine dashed semi-transparent lines are drawn across the band along the found direction: you can see what the search settled on, and the spectrum underneath stays visible. They appear only after Find shear; Find band and Clear calibration reset them, because the shear is measured relative to the band.

Accuracy here is inherently lower than for the band angle: the lever arm is the width of the band, not its length, so at a width of 125 px one pixel of smear is already about 0.45 degrees.

Extracting the spectrum

Capture Spectra (enabled once both the band angle and the shear are measured) opens a window under the preview. Implemented as specified in docs/TZ_Spectrum.md: the wavelength axis is walked and, at every position, all pixels between the band edges are averaged along the spectral-line vector; the ends, where a line does not fully cross the band, are dropped.

The window shows a strip in which the brightness of a point is the value of the spectrum (its height defaults to 1/20 of its width and can be dragged by the handle underneath), and below it the same spectrum as a plot. The height of the window itself is dragged by the handle on its top edge. While the window is open the spectrum is re-extracted from every new frame.

Average N under the plot means the last N spectra are averaged - a plain arithmetic mean - before anything is shown or written out. 1 is off. The history is dropped whenever the spectrum stops covering the same columns, because averaging across a moved crop would smear the lines rather than the noise.

Wavelength calibration

The reference solar spectrum (Delbouille, Neven & Roland 1972, served by BASS2000) lives in data/solar_reference.csv, 300-1130 nm at 0.1 nm; fetch or refresh it with python tools/fetch_reference.py. It is drawn as a second strip flush under ours, blurred to the instrument's resolution and resampled into our pixel columns - the measured spectrum is never resampled.

Calibrate Wavelength turns on line identification; until it is on, the strips ignore clicks. Click a line on the reference (a yellow line follows the cursor there), then the same line on our spectrum (a green one follows there, joined to the first by a sloped segment showing what is being tied to what). Three points finish it. Undo takes back the last click of the session, Reset drops the lot. Points and the fitted polynomial are kept in settings.json; a calibration is either complete or absent, never half of one.

Once it stands: a wavelength scale under the plot, a colour strip showing the visible range, and a cursor line running through the strips and the graph together. Details and the open question of polynomial against a physical model are in docs/TZ_Wavelength.md.

Relative measurement, and getting the curve out

Set baseline keeps the current spectrum aside; everything is then read as a per cent of it. Take one without the filter, put the filter in, and the graph is its transmission curve. Zero and below in the baseline count as one so the division always has something to divide by, and the graph is pinned to 0..100 % because anything above the baseline is noise. Without a baseline the values are per cent of the brightest sample.

Export CSV writes two columns, wavelength and per cent. Export chart draws the same curve as a picture - PNG at 3840x2160 and SVG beside it, with the grid, the colour strip under the axis, the edges of the visible range and the lines that matter for astronomy marked. Both land in captures/.

The transmission curve of an IR-pass filter, measured against a baseline taken without it

The curve above is a no-name IR-pass filter measured this way: transparent below 1 % right across the visible, opening at about 660 nm just short of H-alpha, and the dip near 930 nm is the water vapour band in the room air, not the filter.

Dark frames

Make Dark takes seven covered frames at the current gain and exposure, medians them and files the result as darks/dark_<gain>_<exposure key>.fit, where the key is the position on the exposure scale in whole per cent. Seven is odd on purpose: the median of an even count averages the two middle samples and would break the 16 ADU step of a 12-bit sensor read as RAW16.

Use dark follows what is on disk: it comes on by itself at startup and whenever the gain or exposure lands on a combination that has one, and goes off when it does not. Use bias stands in when there is no dark, taking a flat level off every frame; it is off by default, and note that subtracting a pedestal makes relative measurement meaningless wherever there is no light - the ratio becomes noise divided by noise.

Hardware notes (measured on this machine)

  • RAW16 from an ASI290MM is 12-bit data shifted left by 4. Values are multiples of 16 and full scale is 65535 (tools/probe_camera.py prints "value step 16"), so normalising by 65535 is right and there are 4096 real levels.
  • The camera here is plugged into a USB 2.0 port (IsUSB3Host = False): full-frame RAW16 runs at ~8 fps (~35 MB/s), RAW8 at ~16 fps. On USB 3.0 it will be several times faster. Binning does not help: on a 290MM it is done in software, the full frame still crosses the bus.
  • bandwidth (ASI_BANDWIDTHOVERLOAD) and high_speed are under Advanced.
  • Nothing in the program is model-specific: resolution, control ranges, pixel size, bit depth and the supported formats all come from the SDK. Colour cameras would need debayering, which is not implemented - hence "monochrome".

Next

Which model the X -> wavelength mapping should be. A polynomial is what is implemented; whether the physical grating formula describes this instrument better is still open, and cannot be settled until there is a frame with enough identified lines to hold points back from the fit and measure the residuals on them. See docs/TZ_Wavelength.md.